Шаблон:TGMC apc
Repairing Broken APC[править код]
Файл:TGMC APC Exposed Wires.png
A broken APC is usually a result of xenos slashing it and cutting all the wires.
- Файл:TGMC Wirecutters.png Mend all of the wires (Make sure to wear insulated gloves unless you don't mind getting shocked).
- Файл:TGMC Screwdriver.png Screwdriver the APC to close the cover so that it doesn't get cut in one slash.
Repairing/Relocating APC[править код]
Deconstruction[править код]
In order to relocate/repair a completely destroyed APC (Файл:TGMC APC Broken.png) you will need to deconstruct it.
- Файл:TGMC Screwdriver.png Screwdriver the APC to unexpose the wires if they are exposed (Файл:TGMC APC Exposed Wires.png), make sure the wires are mended first using wirecutters (Файл:TGMC Wirecutters.png). (Or just hit the APC with any tool to remove the cover if it's destroyedФайл:TGMC APC Broken.png)
- (Only if the APC isn't destroyed): Unlock the cover by swiping your ID (or pulsing the right wire with a multitool if your ID doesn't have access) and disengaging the lock on the APC window, and use the crowbar on it to open the cover.
- Remove the power cell with an empty hand.
- Crowbar the floor tile underneath the APC to expose the terminal. (If it is not already exposed)
- Файл:TGMC Wirecutters.png Wire cut the APC to disconnect the terminal. (You will get 10 cable coil)
- Файл:TGMC Screwdriver.png Screwdriver the APC to loosen the power board.
- Crowbar the APC to remove the board. (You won't get a power control board if it's from a destroyed APC)
- Файл:TGMC Blowtorch.gif Weld the APC to get 1 metal and deconstruct it (WARNING: Some areas can have another APC taking over if deconstructed, preventing you from placing a new APC). Or click it with an APC frame (made with 2 metal) to replace and repair it.
Construction[править код]
To construct a new APC you will need to:
- Make an APC frame with 2 metal, dismantle surrounding tables (if any) using wrench if you do not have 2 metal.
- Attach APC frame to a wall (On a more strategic location ideally)
- (Optional) Crowbar the floor tile underneath the APC. (If it is not already exposed)
- Файл:TGMC Cable Coil.png (Optional) Use 10 Cable Coils on the APC to make a terminal. Connect the terminal to the colony's cable power grid if it's powered.
- Insert a Power Control Module (APC) Board. (You can also use the General Circuit Boards if you multitool it to turn it into a APC Board)
- Файл:TGMC Screwdriver.png Screwdriver the APC to secure the board.
- Insert power cell into APC, make sure it has charge.
- Crowbar the APC to close the cover. If left open, xenos can slash the APC to destroy the battery.
- Unlock the APC using an ID with access, or expose the wires and pulse the right wire using multitool if your ID does not have access.
- Turn the main breaker on it starts off by default.
Replacing an APC power cell[править код]
- Assuming the APC is undamaged, first unlock the APC if it is not already with an ID card with APC access.
- Access the interface and disable the cover lock.
- Crowbar open the cover.
- Remove the drained power cell (if there is one) with a free hand.
- Install a charged power cell.
- Crowbar the cover closed.
- (Optional) Lock the APC with the ID. The cover lock will automatically engage.