Guide to Nanites: различия между версиями

Материал из MassMeta
Перейти к навигации Перейти к поиску
imported>Angust
(→‎Utility Programs: Removed double entry for the new sting. Went with Heather's description because it was much better)
imported>Prometheos2
м (Notify about nanites' removal last month. (PR #60473))
 
(не показано 40 промежуточных версий 9 участников)
Строка 1: Строка 1:
{{Important
|Title=Removed
|Image=Paper.png
|Note=<span style="background-color:white"><font color="black"> '''Nanites have been removed from the game in July, 2021'''
([https://github.com/tgstation/tgstation/pull/60473/ PR #60473]). '''This page is archived for historical purposes.'''</font></span>
|Color=#F00
}}
{{Speech
{{Speech
|name=Reynard Parker, the Roboticist
|name=Reynard Parker, the Roboticist
Строка 10: Строка 18:


=Nanites=
=Nanites=
==Research==
Nanite programs are unlocked by researching their relative techweb nodes in the [[Guide_to_Research_and_Development|R&D Console]]. Anything past Basic Nanite Programming, however, will require Nanite research points.
These are gained simply by having active hosts with nanites implanted; the more the merrier. However, non-sentient, non-humanoid, or dead hosts will incur heavy penalties to their research gain.
The Military research node is only available if the Illegal Technology node is unlocked, therefore requiring syndicate tech to be scanned first.<br>
Hazard Nanite Programming is similarly locked behind Alien Technology, which requires [[Abductor]] technology to be scanned to unlock.
==[[File:Nanite chamber.gif]]Implanting==
==[[File:Nanite chamber.gif]]Implanting==
[[File:Nanite_chamber.gif|thumb|right|Use a public nanite chamber to easily implant yourself and others with nanites. You can program them after implanting, by creating a backup cloud with a Cloud control console and adding programs to that cloud. Public nanite chambers will implant nanites synced to cloud 1 by default.]]
[[File:Nanite_chamber.gif|thumb|right|Use a public nanite chamber to easily implant yourself and others with nanites. You can program them after implanting, by creating a backup cloud with a Cloud control console and adding programs to that cloud. Public nanite chambers will implant nanites synced to cloud 1 by default.]]
Nanite implantation can be done through the [[Machines#Nanite_Chamber|Nanite Chamber]]. A second person must operate the chamber from outside and begin the implanting process, at the end of which a new swarm will take root in the host. <br>
Nanite implantation can be done through the [[Machines#Nanite_Chamber|Nanite Chamber]]. A second person must operate the chamber from outside and begin the implanting process, at the end of which a new swarm will take root in the host. <br>
The nanite chamber can edit nanites' Cloud ID, modify the Safety Threshold, or alternatively remove all nanites from a host.


Another easier method is to build a [[Machines#Public_Nanite_Chamber|Public Nanite Chamber]] [[File:Nanite chamber.gif]]. Use a multitool on the Public Nanite Chamber circuit board first to choose which [[#Cloud|backup cloud]] you want it synced to. If you don't multitool the board it will default to [[#Cloud|cloud]] 1. Build the chamber using a machine frame. The public nanite chamber will automatically implant nanites into anyone who enters it, without the need for a second person.  
Another easier method is to build a [[Machines#Public_Nanite_Chamber|Public Nanite Chamber]] [[File:Nanite chamber.gif]]. Use a multitool on the Public Nanite Chamber circuit board first to choose which [[#Cloud|backup cloud]] you want it synced to. If you don't multitool the board it will default to [[#Cloud|cloud]] 1. Build the chamber using a machine frame. The public nanite chamber will automatically implant nanites into anyone who enters it, without the need for a second person.  
Строка 20: Строка 36:
   
   
===[[File:Nanite Scanner.gif]] Nanite Scanner===
===[[File:Nanite Scanner.gif]] Nanite Scanner===
Use this to scan implanted people. It will give you a readout with information about current [[#Volume|nanite volume]], which [[#Nanite_Types|nanite programs]] are currently implanted and their active/inactive status. If a nanite swarm contains the "Stealth" [[#Utility_Programs|utility program]] you will not be able to see the list of programs.  
Use this to scan implanted people. It will give you a readout with information about current [[#Volume|nanite volume]]. If a nanite swarm contains the "Nanite Debugging" [[#Utility_Programs|utility program]] you will also see a list of currently installed [[#Nanite_Types|nanite programs]] and their active/inactive status.  


===[[File:Nanite Remote.gif]] Nanite Remote Control===
===[[File:Nanite Remote.gif]] Nanite Remote Control===
Строка 30: Строка 46:


===[[File:Nanite Remote.gif]] Nanite Communication Remote===
===[[File:Nanite Remote.gif]] Nanite Communication Remote===
A remote used for sending custom messages to the "Skull Echo", "Forced Speech" and "Hallucination (message only)" programs. The settings are very similar to those of the Nanite Remote Control. The difference is you set a ''Comm Code'' and ''Message'' instead of ''Signal Code'' and ''Relay''. The programs installed must have the same ''Comm Code'' to be able to signal them with this remote.
A remote used for sending custom messages on the fly to message-based programs, like Forced Speech. The settings are very similar to those of the Nanite Remote Control. The difference is you set a ''Comm Code'' and ''Message'' instead of ''Signal Code'' and ''Relay''. The programs installed must have the same ''Comm Code'' to be able to signal them with this remote.


==Volume==
==Volume==
If wearing a [[Research_items#Diagnostic_HUD|diagnostic HUD]] [[File:Diag_glasses.png]] you will be able to see a bar next to implanted people, which is a nanite volume meter. Nanites generally expend a part of their volume while their programs are active. Luckily, modern technology allows them to integrate with the host's metabolism to replicate without interfering with biological processes, causing them to have a slow but steady growth rate.  
If wearing a [[Research_items#Diagnostic_HUD|diagnostic HUD]] [[File:Diag_glasses.png]] you will be able to see a bar next to implanted people, which is a nanite volume meter. Nanites generally expend a part of their volume while their programs are active. Luckily, modern technology allows them to integrate with the host's metabolism to replicate without interfering with biological processes, causing them to have a slow but steady growth rate of '''0.5 per second'''. Researching ''Harmonic Nanite Programming'' grants an additional passive volume generation of '''+0.1 per second'''.
 
Nanites by default have a safety threshold where they'll stop using nanite-consuming programs. This threshold can be customized in an individual by entering a [[Machines#Nanite_Chamber|nanite chamber]], and having a second person operate the connected [[Computers#Nanite_Chamber_Control_Console|nanite chamber control console]].If the swarm reaches a population of 0, there's none left to replicate, and the nanites are completely removed.


Nanites by default have a safety threshold where they'll stop using nanite-consuming programs. This threshold can be customized in an individual by entering a [[Machines#Nanite_Chamber|nanite chamber]], and having a second person operate the connected [[Computers#Nanite_Chamber_Control_Console|nanite chamber control console]].If the swarm reaches a population of 0, there's none left to replicate, and the nanites are completely removed.  
Nanite chambers provide the host with 100 nanites. Hosts have a maximum volume of 500 nanites.


==Programming==
==Programming==
Строка 43: Строка 61:


==[[File:Nanite_cloud_controller.gif]]Cloud==
==[[File:Nanite_cloud_controller.gif]]Cloud==
Nanite swarms can be set with a Cloud ID. If so, they will, every 30 seconds, copy the programming of the Cloud Backup with the same ID, if it has been set.
Nanite swarms are usually set with a Cloud ID. If so, they will, every 30 seconds, copy the programming of the Cloud Backup with the same ID.
Cloud backups are controlled by Cloud Control Consoles [[File:Nanite_cloud_controller.gif]]. They can create new backups (with codes from 1 to 100), as well as upload programs from a disk into the selected backup.
Cloud backups are controlled by Cloud Control Consoles [[File:Nanite_cloud_controller.gif]]. They can create new backups (with codes from 1 to 100), as well as upload programs from a disk into the selected backup.
Cloud control consoles [[File:Nanite_cloud_controller.gif]] also serve as storage, meaning that if they're disabled they will no longer sync with connected nanites, and that if all cloud control consoles are destroyed, all backups will be lost.
Cloud control consoles [[File:Nanite_cloud_controller.gif]] also serve as storage, meaning that if they're destroyed all clouds connected to them will be destroyed, and the nanites will be unable to sync to them anymore.
Cloud IDs are unique, meaning that if a console registers an ID, it cannot be used or accessed by other consoles until the original has been destroyed.


Cloud synchronization has several benefits over direct chamber programming: it can update programs without a second person to operate the chamber, it will reset programming in case of tampering or data corruption, and can be updated remotely by a second person. Of course, the last part also makes it very risky, since anyone could upload malicious programs at any time if they have a console to do it with.
Nanites who aren't able to sync to a cloud will keep working, '''but they'll have a chance of encountering software errors every time they miss a synchronization''', causing program deprogramming, deletion, or corruption into dangerous Glitch programs over time.


=Nanite Programs=
=Nanite Programs=
Строка 56: Строка 75:


==[[File:Nanite_programmer.gif]]Customizing Programs==
==[[File:Nanite_programmer.gif]]Customizing Programs==
Programs have sevral parameters that can be customized with the use of a [[Machines#Nanite_Programmer|Nanite Programmer]] [[File:Nanite_programmer.gif]]. Simply insert a program disk in the machine and set the parameters you prefer.
Programs have several parameters that can be customized with the use of a [[Machines#Nanite_Programmer|Nanite Programmer]] [[File:Nanite_programmer.gif]]. Simply insert a program disk in the machine and set the parameters you prefer.
Note that codes set to 0 are inactive and cannot be signaled.
Note that codes set to 0 are inactive and cannot be signaled.


* Activated: Determines if the program starts activated or not.
* Activated: Determines if the program starts activated or not.
* Activation Delay: Determines, in seconds, how long until the program self-activates.
 
* Timer: Determines the length of the timer. Disables the timer if set to 0.
* Restart Timer: If set, automatically re-activates the program after X seconds whenever deactivated.
* Timer Type: Determines what happens when the timer counts down. Has four settings:
* Shutdown Timer: If set, automatically deactivates the program after X seconds whenever activated.
** Deactivate: Deactivates the program.
* Trigger Timer: (Only for triggered programs) If set, automatically triggers the program every X seconds, if possible.
** Self-Delete: Deletes the program.
* Trigger Delay: (Only for triggered programs) If set, delays trigger signals by X seconds.
** Trigger: Triggers the program, if possible.
 
** Reset Activation Timer: If there is an activation timer, it's reset to 0, deactivating the program until it counts down again.
* Activation Code: The code that must be signaled to activate the program.
* Activation Code: The code that must be signaled to activate the program.
* Deactivation Code: The code that must be signaled to deactivate the program.
* Deactivation Code: The code that must be signaled to deactivate the program.
Строка 72: Строка 90:
* Kill Code: The code that must be signaled to delete the program.
* Kill Code: The code that must be signaled to delete the program.


Some programs have an extra setting available for customization, like relay channels or signal codes.
Some programs have a extra settings available for customization, like relay channels or signal codes.


==Signaling Programs==
==Signaling Programs==
Строка 78: Строка 96:


Nanite Remotes can be set to four modes:
Nanite Remotes can be set to four modes:
* Self targets the person who is holding the remote.
* '''Self''' targets the person who is holding the remote.
* Targeted targets only the mob that is being clicked on.
* '''Targeted''' targets only the mob that is being clicked on.
* Area targets all mobs in sight.
* '''Area''' targets all mobs in sight.
* Relay allows the user to choose a relay channel; the signal is then sent globally to all hosts which have a relay program set to that channel.
* '''Relay''' allows the user to choose a relay channel; the signal is then sent globally to all hosts which have a relay program set to that channel.


==Triggered Programs==
==Triggered Programs==
Строка 87: Строка 105:
Triggering a program generally has a cooldown as well as a cost in volume; if those requirements are not met the program won't trigger.
Triggering a program generally has a cooldown as well as a cost in volume; if those requirements are not met the program won't trigger.
If the program is not activated, it will also be unable to trigger, but activating the program is not the same as triggering it.
If the program is not activated, it will also be unable to trigger, but activating the program is not the same as triggering it.
==Program Rules==
Sensor programs can also be installed as Rules to other installed programs. When doing so, that program will only work or be triggered if it satisfies the conditions of the sensor program.
To install a Sensor program as a Rule, customize the sensor program in the Nanite Programmer, insert the disk in the Cloud Console, and press the Add Rule button on the program you want to install it on.
For example, installing a Health < 30% sensor to a Bio-Reconstruction program will allow you to only use that program when the host is severely harmed.
Note that rules are cumulative with Activation status: a Deactivated program will not work even if it satisfies the Rule condition, and an Activated program that does not meet the rule requirements won't work either.


==Data Corruption==
==Data Corruption==
Events like EMPs or shocks might result in data corruption in nanite programs, which can result in one of several different effects:
Lack of constant cloud sync, as well as events like EMPs or shocks, can result in data corruption in nanite programs, which results in one of the following effects:
- Toggles the program, deactivating it if active and viceversa.
* Toggles the program, deactivating it if active and viceversa.
- Triggers the program, if it can be triggered
* Triggers the program, if it can be triggered
- Deletes the program completely
* Deletes the program completely
- Resets all the codes, preventing it from being signaled by remotes or signal programs.
* Resets all the codes, preventing it from being signaled by remotes or signal programs.
- Converts the program into a corrupted version. The glitch program depends on the program that got corrupted.
* Converts the program into a corrupted version. The glitch program depends on the program that got corrupted.


==Nanite Types==
Cloud Syncing generally prevents data corruption from being dangerous. Remaining unlinked from the cloud console (either because the console is missing, or because of manual unlinking from the chamber) means that nanites are subject to decay, leading to the nanites becoming ineffective at best, and very dangerous at worst.
Nanites are split in several categories.
 
==Nanite Program Types==
Programs are split in several categories.


===Utility Programs===
===Utility Programs===
Строка 118: Строка 147:
| --
| --
| Smart
| Smart
| Toxin Buildup
|-
!Distributed Computing
| The nanites aid the research servers by performing a portion of its calculations, increasing research point generation by a flat amount for each host currently running this program. Non-sentient hosts generate only 25% of the research gain.
| 0.2
| --
| --
| Basic
| Toxin Buildup
|-
!Neural Network
| The nanites aid the research servers by cross-referencing data from all their active hosts. Gives a research boost that becomes more powerful for each host currently running this program, overtaking Distributed Computing at 12 hosts. Non-sentient hosts generate only 25% of the research gain and efficiency boost.
| 0.3
| --
| --
| Basic
| Toxin Buildup
| Toxin Buildup
|-
|-
!Viral Replica
!Viral Replica
| The nanites constantly send encrypted signals attempting to forcefully copy their own programming into other nanite clusters.
| The nanites constantly send encrypted signals attempting to forcefully copy their own programming into other nanite clusters. This program will also forcefully set their cloud ID to 0 (disabled) or a customized ID.
| 0.5
| 0.5
| --
| --
Строка 129: Строка 174:
|-
|-
!Monitoring
!Monitoring
| The nanites monitor the host's vitals and location, sending them to the suit sensor network.
| The nanites monitor the host's vitals and location, sending them to the suit sensor network. Additionally adds a nanite HUD icon to medHUDs looking at the host.
| 0
| 0
| --
| --
Строка 137: Строка 182:
|-
|-
!Host Scan
!Host Scan
| The nanites display a detailed readout of a body scan to the host. Can pick between medical, chemical, or nanite scan.
| The nanites display a detailed readout of a body scan to the host when triggered. Can pick between medical, chemical, or nanite scan.
| --
| --
| 3
| 3
Строка 145: Строка 190:
|-
|-
!Stealth
!Stealth
| The nanites hide their activity and programming from superficial scans.
| The nanites hide their activity from superficial scans, making them invisible to Diagnostic HUDs and immune to Viral programs.
| 0.2
| 0.2
| --
| --
| --
| --
| Smart
| Smart
| Toxin Buildup
|-
!Nanite Debugging
| Enables various high-cost diagnostics in the nanites, making them able to communicate their program list to [[#Nanite_Scanner|nanite scanners]]. Doing so uses some power, slightly decreasing their replication speed.
| 0.1
| --
| --
| Basic
| Toxin Buildup
| Toxin Buildup
|-
|-
!Subdermal ID
!Subdermal ID
| The nanites store the host's ID access rights in a subdermal magnetic strip. Updates when triggered, copying the host's current access.
| The nanites store the host's ID access rights in a subdermal magnetic strip. Updates when triggered, copying the access of the host's worn or pulled ID.
| --
| --
| 0
| 0
Строка 159: Строка 212:
| Basic
| Basic
| Dermalysis
| Dermalysis
|-
!Dermal Button
| The nanites form a button on the host's arm, allowing them to manually send a signal to the nanites when pressed. The button will display in the host's action bar, and can be customized in name, icon shape, color, and of course sent signal. The button cannot be pressed while the host is incapacitated.
| --
| 0
| --
| Mesh
| Glitch
|-
|-
!Relay
!Relay
Строка 186: Строка 247:
!Infective Exo-Locomotion
!Infective Exo-Locomotion
| The nanites gain the ability to survive for brief periods outside of the human body, as well as the ability to start new colonies without an integration process; resulting in an extremely infective strain of nanites.
| The nanites gain the ability to survive for brief periods outside of the human body, as well as the ability to start new colonies without an integration process; resulting in an extremely infective strain of nanites.
| 5.5
| 1.5
| --
| --
| --
| --
Строка 198: Строка 259:
| 10s
| 10s
| Military
| Military
| Glitch , Toxic
| Glitch, Toxic
|-
|-
!Mitosis
!Mitosis
| The nanites gain the ability to self-replicate, using bluespace to power the process, instead of using the host's metabolism. This rapidly speeds up the replication rate, but it causes occasional software errors due to faulty copies. Will not activate if the nanites are synced to a cloud backup.
| The nanites gain the ability to self-replicate, using bluespace to power the process, instead of using the host's metabolism. This rapidly speeds up the replication rate, but it causes occasional software errors due to faulty copies, making it very dangerous when used without a cloud connection.
| +0.5 to +5
| +0.5 to +5
| --
| --
Строка 215: Строка 276:
| Mesh
| Mesh
| Toxin Buildup
| Toxin Buildup
|-
|}
===Protocols===
Special programs that enhance nanite behaviour in one particular sector. Only one protocol of each category can function at the same time in a nanite cloud.
These are unlocked through [[bepis|B.E.P.I.S.]] research.
{| class="wikitable sortable" border="1" width=100%; || style="text-align: center;"
|-
! scope="col" width=10% | Program
! scope="col" class="unsortable" | Effect
! scope="col" width=5% | Volume per second
! scope="col" width=5% | Trigger Cost
! scope="col" width=5% | Trigger Cooldown
! scope="col" width=5% | Category
! scope="col" width=7% | Required Techweb
! scope="col" class="unsortable" width=8% | Corruptions
|-
!Kickstart Protocol
| The nanites focus on early growth, heavily boosting replication rate for a few minutes after the initial implantation.
| +3.5(for the first 120 seconds)
| --
| --
| Replication
| Nanite Replication Protocols
| Necrosis
|-
!Factory Protocol
| The nanites build a factory matrix within the host, gradually increasing replication speed over time. The factory decays if the protocol is not active, and can be damaged by shocks or EMPs.
| --
| --
| --
| Replication
| Nanite Replication Protocols
| Necrosis
|-
!Pyramid Protocol
| The nanites implement an alternate cooperative replication protocol that is more efficient as long as the saturation level is above 80%.
| +1.2(if volume above 80%)
| --
| --
| Replication
| Nanite Replication Protocols
| Necrosis
|-
!Offline Production Protocol
| While the host is asleep or otherwise unconcious, the nanites exploit the reduced interference to replicate much faster.
| +3(if asleep)
| --
| --
| Replication
| Nanite Replication Protocols
| Necrosis
|-
!Hive Protocol
| The nanites use a more efficient grid arrangment for volume storage, increasing maximum volume in a host by 250.
| --
| --
| --
| Storage
| Nanite Storage Protocols
| Necrosis
|-
!Zip Protocol
| The nanites are disassembled and compacted when unused, increasing the maximum volume while in a host by 500. However, the process slows down the replication rate slightly.
| 0.2
| --
| --
| Storage
| Nanite Storage Protocols
| Necrosis
|-
!Free Range Protocol
| The nanites discard their default storage protocols in favour of a cheaper and more organic approach. Reduces maximum volume by 250, but increases the replication rate.
| +0.5
| --
| --
| Storage
| Nanite Storage Protocols
| Necrosis
|-
!S.L.O. Protocol
| 'S.L.O.P.', or Storage Level Override Protocol, completely disables the safety measures normally present in nanites, allowing them to reach much higher saturation levels (1500 extra volume), but at the risk of causing internal damage to the host.
| --
| --
| --
| Storage
| Nanite Storage Protocols
| Necrosis
|-
|-
|}
|}
Строка 240: Строка 390:
|-
|-
!Dermal Hardening
!Dermal Hardening
| The nanites form a mesh under the host's skin, protecting them from melee and bullet impacts.
| The nanites form a mesh under the host's skin, protecting them from melee and bullet impacts. Adds 25 melee and 20 bullet armor.  
| 0.5
| 0.5
| --
| --
Строка 248: Строка 398:
|-
|-
!Dermal Refractive Surface
!Dermal Refractive Surface
| The nanites form a membrane above the host's skin, reducing the effect of laser and energy impacts.
| The nanites form a membrane above the host's skin, reducing the effect of laser and energy impacts. Adds 25 laser and 20 energy armor.  
| 0.5
| 0.5
| --
| --
Строка 255: Строка 405:
| Dermalysis
| Dermalysis
|-
|-
!Rapid Coagulation
!Vein Repressurization
| The nanites induce rapid coagulation when the host is wounded, dramatically reducing bleeding rate.
| Reduces bleeding rate by 50%.  
| 0.1
| 0.2
| --
| --
| --
| --
Строка 278: Строка 428:
| Synaptic
| Synaptic
| Neuro-Necrosis, Brain Misfire
| Neuro-Necrosis, Brain Misfire
|-
!Adrenaline Burst
| The nanites cause a burst of adrenaline when triggered, injecting 3 units of [[Guide_to_chemistry#Experimental_Stimulants|Experimental Stimulants]] waking the host and temporarily increasing their speed, while also causing them to drop items.
| --
| 25
| 120s
| Harmonic
| Toxin Buildup, Nerve Decay
|}
|}


Строка 302: Строка 444:
|-
|-
!Accelerated Regeneration
!Accelerated Regeneration
| The nanites boost the host's natural regeneration, increasing their healing speed. <i>Does not consume nanites while the host is undamaged.</i>
| The nanites boost the host's natural regeneration, healing them slowly over time (0.5 brute and burn). <i>Does not consume nanites while the host is undamaged.</i>
| 2.5
| 0.5
| --
| --
| --
| --
Строка 318: Строка 460:
|-
|-
!Blood Purification
!Blood Purification
| The nanites purge toxins and chemicals from the host's bloodstream. Does not consume nanites if the host has no chemicals nor toxin damage.
| The nanites purge 1 toxin damage and 1u of all chemicals from the host's bloodstream. Like most other programs it consumes nanites even if it has no effect (change from Aug, 2020).  
| 1
| 1
| --
| --
Строка 326: Строка 468:
|-
|-
!Neural Regeneration
!Neural Regeneration
| The nanites fix neural connections in the host's brain, reversing brain damage and minor traumas. Does not consume nanites if the host has no brain damage.
| The nanites fix neural connections in the host's brain, reversing brain damage and minor traumas. Does not consume nanites if the host has no brain damage. Heals 1 brain damage and has 10% chance to heal basic level [[Guide_to_Traumas#Basic_Traumas_Without_Prefix|brain traumas]].  
| 1.5
| 1.5
| --
| --
Строка 342: Строка 484:
|-
|-
!Mechanical Repair
!Mechanical Repair
| The nanites fix damage in the host's mechanical limbs. Does not consume nanites if the limbs are undamaged.
| The nanites fix damage in the host's mechanical limbs. Heals 1 brute and burn spread across damaged limbs. Does not consume nanites if the limbs are undamaged.
| 0.5
| 0.5
| --
| --
| --
| --
| Basic
| Necrosis
| Necrosis
|-
|-
!Selective Blood Purification
!Selective Blood Purification
| The nanites purge toxins and dangerous chemicals from the host's bloodstream, while ignoring beneficial chemicals. The added processing power required to analyze the chemicals severely increases the nanite consumption rate.
| The nanites purge 1 toxin damage and 1u [[Guide_to_chemistry#Toxins|toxin]] reagents from the host's bloodstream, while ignoring non-toxin chemicals. The added processing power required to analyze the chemicals severely increases the nanite consumption rate.
| 2
| 2
| --
| --
Строка 357: Строка 500:
|-
|-
!Bio-Reconstruction
!Bio-Reconstruction
| The nanites manually repair and replace organic cells, acting much faster than normal regeneration. However, this program cannot detect the difference between harmed and unharmed, causing it to consume nanites even if it has no effect.
| The nanites manually repair and replace organic cells, acting much faster than normal regeneration. However, this program cannot detect the difference between harmed and unharmed, causing it to consume nanites even if it has no effect. Heals 2 brute and burn damage.  
| 5.5
| 5.5
| --
| --
Строка 365: Строка 508:
|-
|-
!Neural Reimaging
!Neural Reimaging
| The nanites are able to backup and restore the host's neural connections, potentially replacing entire chunks of missing or damaged brain matter.
| The nanites are able to backup and restore the host's neural connections, potentially replacing entire chunks of missing or damaged brain matter. Heals 2 brain damage and has 10% chance to heal up to lobotomy level [[Guide_to_Traumas#Deep-rooted_Prefix|brain traumas]].  
| 3
| 3
| --
| --
Строка 373: Строка 516:
|-
|-
!Defibrillation
!Defibrillation
| The nanites shock the host's heart when triggered, bringing them back to life if the body can sustain it. Ghost has 8 seconds to re-enter their body after the trigger. The host can not have 200 or more total damage (including toxin and oxyloss damage) or the revive will fail. Unlike with ordinary defibrillators (just need less than 180 brute and burn) the revive will not heal or cause any oxyloss or other damage, which means it's possible to stand up instantly if hurt less than crit threshold.  
| The nanites shock the host's heart when triggered, bringing them back to life if the body can sustain it. The revive has the same requirements to work as an ordinary [[Guide_to_medicine#Defibrillation|defibrillation]], except the revive will not heal toxin or suffocation damage, and will not deal any suffocation damage. This means the body must have under 180 total of all basic damage types + cellular. The ghost gets a message and 8 seconds to re-enter their body after the trigger.  
| --
| --
| 25
| 25
Строка 520: Строка 663:
| Military
| Military
| Toxin Buildup
| Toxin Buildup
|-
!Heart-Stopper
| Stops the host's heart when triggered; restarts it if triggered again.
| 0
| 12
| 1s
| Military
| Nerve Decay
|-
|-
!Cryogenic Treatment
!Cryogenic Treatment
Строка 546: Строка 681:
|-
|-
!Mind Control
!Mind Control
| The nanites imprint an absolute directive onto the host's brain while they're active.
| The nanites imprint an absolute directive onto the host's brain for 60 seconds when triggered. Can be used with a Comm Remote.
| 3
| --
| --
| --
| 30
| 180s
| Hazard
| Hazard
| Neuro-Necrosis, Brain Misfire  
| Neuro-Necrosis, Brain Misfire  
Строка 569: Строка 704:
|-
|-
!Electric Shock
!Electric Shock
| The nanites shock the host when triggered. Destroys a large amount of nanites!
| The nanites shock the host when triggered. This will still harm nanites, causing volume loss and potential program errors.
| --
| --
| 10
| 10
Строка 593: Строка 728:
|-
|-
!Paralysis
!Paralysis
| The nanites actively suppress nervous pulses, effectively paralyzing the host.
| The nanites actively suppress nervous pulses, effectively paralyzing the host while active.
| 3
| 3
| --
| --
Строка 599: Строка 734:
| Neural
| Neural
| Nerve Decay
| Nerve Decay
|-
!Happiness Enhancer
| The nanites synthesize serotonin inside the host's brain, creating an artificial sense of happiness.
| 0.1
| --
| --
| Neural
| Neuro-Necrosis
|-
!Happiness Suppressor
| The nanites suppress the production of serotonin inside the host's brain, creating an artificial state of depression.
| 0.1
| --
| --
| Neural
| Neuro-Necrosis
|-
|-
!Death Simulation
!Death Simulation
Строка 719: Строка 870:
| Glitch
| Glitch
|-
|-
!Species Sensor
| When triggered, the nanites scan the host and output a signal if the host's species matches the one set in the program's settings. The options include "Human", "Lizard", "Moth", "Ethereal", "Pod", "Fly", "Felinid", "Jelly" and "Other". Secondary toggle is either "Is" or "Is Not".
| --
| --
| --
| Biological
| Glitch
|}
|}
[[Category:Guides]] [[Category:Removed Content]]

Текущая версия от 01:06, 9 августа 2021

Файл:Paper.png Removed

Nanites have been removed from the game in July, 2021 (PR #60473). This page is archived for historical purposes.


Файл:Roboticist action.png
 
Reynard Parker, the Roboticist говорит:
"Move over Geneticist, there's a better way of making super humans these days. What is this method, you may ask? Nanites, son. It's not without its risks to the user, but it's not like anybody is going to detonate anybody from the inside out with these things, right...?"


Nanites are tiny nanomachines that live in a host's bloodstream, providing different functionalities depending on how they're programmed. The mob where the nanites reside is usually defined as their host.

Nanites[править | править код]

Research[править | править код]

Nanite programs are unlocked by researching their relative techweb nodes in the R&D Console. Anything past Basic Nanite Programming, however, will require Nanite research points. These are gained simply by having active hosts with nanites implanted; the more the merrier. However, non-sentient, non-humanoid, or dead hosts will incur heavy penalties to their research gain.

The Military research node is only available if the Illegal Technology node is unlocked, therefore requiring syndicate tech to be scanned first.
Hazard Nanite Programming is similarly locked behind Alien Technology, which requires Abductor technology to be scanned to unlock.

Файл:Nanite chamber.gifImplanting[править | править код]

Файл:Nanite chamber.gif
Use a public nanite chamber to easily implant yourself and others with nanites. You can program them after implanting, by creating a backup cloud with a Cloud control console and adding programs to that cloud. Public nanite chambers will implant nanites synced to cloud 1 by default.

Nanite implantation can be done through the Nanite Chamber. A second person must operate the chamber from outside and begin the implanting process, at the end of which a new swarm will take root in the host.
The nanite chamber can edit nanites' Cloud ID, modify the Safety Threshold, or alternatively remove all nanites from a host.

Another easier method is to build a Public Nanite Chamber Файл:Nanite chamber.gif. Use a multitool on the Public Nanite Chamber circuit board first to choose which backup cloud you want it synced to. If you don't multitool the board it will default to cloud 1. Build the chamber using a machine frame. The public nanite chamber will automatically implant nanites into anyone who enters it, without the need for a second person.

Nanite Tools[править | править код]

There are currently three handheld tools that can be used to manage nanites. You can print them from the science protolathe after researching some basic nanites.

Файл:Nanite Scanner.gif Nanite Scanner[править | править код]

Use this to scan implanted people. It will give you a readout with information about current nanite volume. If a nanite swarm contains the "Nanite Debugging" utility program you will also see a list of currently installed nanite programs and their active/inactive status.

Файл:Nanite Remote.gif Nanite Remote Control[править | править код]

A remote used for sending signals to implanted nanites. Change its settings and then click anywhere or on a target to activate it. For example you can set the code to be the trigger code you gave the "Host Scan" program. Using this in hand will open a menu. Settings:

  • Signal Code: Which code you want it to signal.
  • Signal Mode: Choose between "off" (makes remote do nothing), "local" (only signals the user), "targeted" (signals whoever you click directly on), "area" (signals anyone within your line of sight) and "relay" (signals any existing nanite programs that have a chosen "relay code").
  • Save Current Setting: Lets you save current setting to a list, with a name of choice. Not saved between rounds.
  • Lock Interface: Locks the settings. Alt-click the remote to unlock.

Файл:Nanite Remote.gif Nanite Communication Remote[править | править код]

A remote used for sending custom messages on the fly to message-based programs, like Forced Speech. The settings are very similar to those of the Nanite Remote Control. The difference is you set a Comm Code and Message instead of Signal Code and Relay. The programs installed must have the same Comm Code to be able to signal them with this remote.

Volume[править | править код]

If wearing a diagnostic HUD you will be able to see a bar next to implanted people, which is a nanite volume meter. Nanites generally expend a part of their volume while their programs are active. Luckily, modern technology allows them to integrate with the host's metabolism to replicate without interfering with biological processes, causing them to have a slow but steady growth rate of 0.5 per second. Researching Harmonic Nanite Programming grants an additional passive volume generation of +0.1 per second.

Nanites by default have a safety threshold where they'll stop using nanite-consuming programs. This threshold can be customized in an individual by entering a nanite chamber, and having a second person operate the connected nanite chamber control console.If the swarm reaches a population of 0, there's none left to replicate, and the nanites are completely removed.

Nanite chambers provide the host with 100 nanites. Hosts have a maximum volume of 500 nanites.

Programming[править | править код]

Nanite swarms can contain nanite programs. These programs can have a huge variety of effects, and are loaded into a nanite swarm in two main ways: uploading them manually with a nanite chamber or by syncing them with a Cloud Backup. Once loaded programs cannot be directly modified; instead, a copy of the same program with the desired programming must be uploaded again to overwrite the previous one. There is no limit to the amount of loaded programs, but using too many at once will usually rapidly deplete the nanite population.

Cloud[править | править код]

Nanite swarms are usually set with a Cloud ID. If so, they will, every 30 seconds, copy the programming of the Cloud Backup with the same ID. Cloud backups are controlled by Cloud Control Consoles . They can create new backups (with codes from 1 to 100), as well as upload programs from a disk into the selected backup. Cloud control consoles also serve as storage, meaning that if they're destroyed all clouds connected to them will be destroyed, and the nanites will be unable to sync to them anymore. Cloud IDs are unique, meaning that if a console registers an ID, it cannot be used or accessed by other consoles until the original has been destroyed.

Nanites who aren't able to sync to a cloud will keep working, but they'll have a chance of encountering software errors every time they miss a synchronization, causing program deprogramming, deletion, or corruption into dangerous Glitch programs over time.

Nanite Programs[править | править код]

Nanite programs determine what nanites do inside the host. They have different categories, and range from helpful to deadly.

Obtaining programs[править | править код]

Programs are unlocked through techweb research. Once unlocked, they can be downloaded into Nanite Program Disks at a Nanite Program Hub .

Customizing Programs[править | править код]

Programs have several parameters that can be customized with the use of a Nanite Programmer . Simply insert a program disk in the machine and set the parameters you prefer. Note that codes set to 0 are inactive and cannot be signaled.

  • Activated: Determines if the program starts activated or not.
  • Restart Timer: If set, automatically re-activates the program after X seconds whenever deactivated.
  • Shutdown Timer: If set, automatically deactivates the program after X seconds whenever activated.
  • Trigger Timer: (Only for triggered programs) If set, automatically triggers the program every X seconds, if possible.
  • Trigger Delay: (Only for triggered programs) If set, delays trigger signals by X seconds.
  • Activation Code: The code that must be signaled to activate the program.
  • Deactivation Code: The code that must be signaled to deactivate the program.
  • Trigger Code: If the program can be triggered, the code that must be signaled to trigger the program.
  • Kill Code: The code that must be signaled to delete the program.

Some programs have a extra settings available for customization, like relay channels or signal codes.

Signaling Programs[править | править код]

Nanite Remotes can send coded signals to nanites. When a nanite swarm receives a signal, all its programs react if they recognize the code.

Nanite Remotes can be set to four modes:

  • Self targets the person who is holding the remote.
  • Targeted targets only the mob that is being clicked on.
  • Area targets all mobs in sight.
  • Relay allows the user to choose a relay channel; the signal is then sent globally to all hosts which have a relay program set to that channel.

Triggered Programs[править | править код]

Some programs do not have an effect over time, and instead must be triggered. To do so they can either receive a Trigger Code or set a Trigger Timer. Triggering a program generally has a cooldown as well as a cost in volume; if those requirements are not met the program won't trigger. If the program is not activated, it will also be unable to trigger, but activating the program is not the same as triggering it.

Program Rules[править | править код]

Sensor programs can also be installed as Rules to other installed programs. When doing so, that program will only work or be triggered if it satisfies the conditions of the sensor program.

To install a Sensor program as a Rule, customize the sensor program in the Nanite Programmer, insert the disk in the Cloud Console, and press the Add Rule button on the program you want to install it on.

For example, installing a Health < 30% sensor to a Bio-Reconstruction program will allow you to only use that program when the host is severely harmed.

Note that rules are cumulative with Activation status: a Deactivated program will not work even if it satisfies the Rule condition, and an Activated program that does not meet the rule requirements won't work either.

Data Corruption[править | править код]

Lack of constant cloud sync, as well as events like EMPs or shocks, can result in data corruption in nanite programs, which results in one of the following effects:

  • Toggles the program, deactivating it if active and viceversa.
  • Triggers the program, if it can be triggered
  • Deletes the program completely
  • Resets all the codes, preventing it from being signaled by remotes or signal programs.
  • Converts the program into a corrupted version. The glitch program depends on the program that got corrupted.

Cloud Syncing generally prevents data corruption from being dangerous. Remaining unlinked from the cloud console (either because the console is missing, or because of manual unlinking from the chamber) means that nanites are subject to decay, leading to the nanites becoming ineffective at best, and very dangerous at worst.

Nanite Program Types[править | править код]

Programs are split in several categories.

Utility Programs[править | править код]

Programs that interact with the nanites themselves, or have general utility purposes.

Program Effect Volume per second Trigger Cost Trigger Cooldown Required Techweb Corruptions
Metabolic Synthesis The nanites use the metabolic cycle of the host to speed up their replication rate, using their extra nutrition as fuel. The host must be at least well fed. +0.5 -- -- Smart Toxin Buildup
Distributed Computing The nanites aid the research servers by performing a portion of its calculations, increasing research point generation by a flat amount for each host currently running this program. Non-sentient hosts generate only 25% of the research gain. 0.2 -- -- Basic Toxin Buildup
Neural Network The nanites aid the research servers by cross-referencing data from all their active hosts. Gives a research boost that becomes more powerful for each host currently running this program, overtaking Distributed Computing at 12 hosts. Non-sentient hosts generate only 25% of the research gain and efficiency boost. 0.3 -- -- Basic Toxin Buildup
Viral Replica The nanites constantly send encrypted signals attempting to forcefully copy their own programming into other nanite clusters. This program will also forcefully set their cloud ID to 0 (disabled) or a customized ID. 0.5 -- -- Military Toxin Buildup
Monitoring The nanites monitor the host's vitals and location, sending them to the suit sensor network. Additionally adds a nanite HUD icon to medHUDs looking at the host. 0 -- -- Basic Toxin Buildup
Host Scan The nanites display a detailed readout of a body scan to the host when triggered. Can pick between medical, chemical, or nanite scan. -- 3 5s Neural Toxin Buildup
Stealth The nanites hide their activity from superficial scans, making them invisible to Diagnostic HUDs and immune to Viral programs. 0.2 -- -- Smart Toxin Buildup
Nanite Debugging Enables various high-cost diagnostics in the nanites, making them able to communicate their program list to nanite scanners. Doing so uses some power, slightly decreasing their replication speed. 0.1 -- -- Basic Toxin Buildup
Subdermal ID The nanites store the host's ID access rights in a subdermal magnetic strip. Updates when triggered, copying the access of the host's worn or pulled ID. -- 0 5s Basic Dermalysis
Dermal Button The nanites form a button on the host's arm, allowing them to manually send a signal to the nanites when pressed. The button will display in the host's action bar, and can be customized in name, icon shape, color, and of course sent signal. The button cannot be pressed while the host is incapacitated. -- 0 -- Mesh Glitch
Relay The nanites receive and relay long-range nanite signals. Must be set with a relay channel beforehand. -- -- -- Basic Toxin Buildup
Signal Repeater When triggered, sends another signal to the host, optionally with a delay. Useful to set up multiple codes for the same program. -- -- -- Basic Toxin Buildup
Relay Signal Repeater When triggered, sends a signal via relay, optionally with a delay. -- -- -- Basic Toxin Buildup
Infective Exo-Locomotion The nanites gain the ability to survive for brief periods outside of the human body, as well as the ability to start new colonies without an integration process; resulting in an extremely infective strain of nanites. 1.5 -- -- Hazard Hypoxemia, Necrosis
Nanite Sting When triggered stings a random non-host around the host with a barely-visible cluster of nanites, making them a new host. The target will feel it. If the cluster finds no valid targets, it returns to the original host, "refunding" the trigger cost. -- 5 10s Military Glitch, Toxic
Mitosis The nanites gain the ability to self-replicate, using bluespace to power the process, instead of using the host's metabolism. This rapidly speeds up the replication rate, but it causes occasional software errors due to faulty copies, making it very dangerous when used without a cloud connection. +0.5 to +5 -- -- Hazard Toxic
Electromagnetic Resonance The nanites cause an elctromagnetic pulse around the host when triggered. Will corrupt other nanite programs! 0 10 5s Mesh Toxin Buildup

Protocols[править | править код]

Special programs that enhance nanite behaviour in one particular sector. Only one protocol of each category can function at the same time in a nanite cloud. These are unlocked through B.E.P.I.S. research.

Program Effect Volume per second Trigger Cost Trigger Cooldown Category Required Techweb Corruptions
Kickstart Protocol The nanites focus on early growth, heavily boosting replication rate for a few minutes after the initial implantation. +3.5(for the first 120 seconds) -- -- Replication Nanite Replication Protocols Necrosis
Factory Protocol The nanites build a factory matrix within the host, gradually increasing replication speed over time. The factory decays if the protocol is not active, and can be damaged by shocks or EMPs. -- -- -- Replication Nanite Replication Protocols Necrosis
Pyramid Protocol The nanites implement an alternate cooperative replication protocol that is more efficient as long as the saturation level is above 80%. +1.2(if volume above 80%) -- -- Replication Nanite Replication Protocols Necrosis
Offline Production Protocol While the host is asleep or otherwise unconcious, the nanites exploit the reduced interference to replicate much faster. +3(if asleep) -- -- Replication Nanite Replication Protocols Necrosis
Hive Protocol The nanites use a more efficient grid arrangment for volume storage, increasing maximum volume in a host by 250. -- -- -- Storage Nanite Storage Protocols Necrosis
Zip Protocol The nanites are disassembled and compacted when unused, increasing the maximum volume while in a host by 500. However, the process slows down the replication rate slightly. 0.2 -- -- Storage Nanite Storage Protocols Necrosis
Free Range Protocol The nanites discard their default storage protocols in favour of a cheaper and more organic approach. Reduces maximum volume by 250, but increases the replication rate. +0.5 -- -- Storage Nanite Storage Protocols Necrosis
S.L.O. Protocol 'S.L.O.P.', or Storage Level Override Protocol, completely disables the safety measures normally present in nanites, allowing them to reach much higher saturation levels (1500 extra volume), but at the risk of causing internal damage to the host. -- -- -- Storage Nanite Storage Protocols Necrosis

Augmentation Programs[править | править код]

Augmentation programs offer boosts and bonuses to the host.

Program Effect Volume per second Trigger Cost Trigger Cooldown Required Techweb Corruptions
Nerve Support The nanites act as a secondary nervous system, reducing the amount of time the host is stunned by half. 1.5 -- -- Neural Nerve Decay
Dermal Hardening The nanites form a mesh under the host's skin, protecting them from melee and bullet impacts. Adds 25 melee and 20 bullet armor. 0.5 -- -- Mesh Dermalysis
Dermal Refractive Surface The nanites form a membrane above the host's skin, reducing the effect of laser and energy impacts. Adds 25 laser and 20 energy armor. 0.5 -- -- Mesh Dermalysis
Vein Repressurization Reduces bleeding rate by 50%. 0.2 -- -- Biological Hypoxemia
Electric Conduction The nanites act as a grounding rod for electric shocks, protecting the host. Shocks can still damage the nanites themselves. 0.2 -- -- Mesh Nerve Decay
Mental Barrier The nanites form a protective membrane around the host's brain, shielding them from abnormal influences like a mindshield implant while they're active. 0.4 -- -- Synaptic Neuro-Necrosis, Brain Misfire

Healing Programs[править | править код]

Healing programs fix a variety of damage and ailments that affect the host. They generally consume a lot of nanites, so it's advisable to activate them manually when necessary.

Program Effect Volume per second Trigger Cost Trigger Cooldown Required Techweb Corruptions
Accelerated Regeneration The nanites boost the host's natural regeneration, healing them slowly over time (0.5 brute and burn). Does not consume nanites while the host is undamaged. 0.5 -- -- Biological Necrosis
Temperature Adjustment The nanites adjust the host's internal temperature to an ideal level. Does not consume nanites while the host is at an ideal temperature. 3.5 -- -- Mesh Dermalysis
Blood Purification The nanites purge 1 toxin damage and 1u of all chemicals from the host's bloodstream. Like most other programs it consumes nanites even if it has no effect (change from Aug, 2020). 1 -- -- Smart Hypoxemia, Necrosis
Neural Regeneration The nanites fix neural connections in the host's brain, reversing brain damage and minor traumas. Does not consume nanites if the host has no brain damage. Heals 1 brain damage and has 10% chance to heal basic level brain traumas. 1.5 -- -- Neural Neuro-Necrosis
Blood Regeneration The nanites stimulate and boost blood cell production in the host. Does not consume nanites if the host has enough blood. 1 -- -- Biological Hypoxemia
Mechanical Repair The nanites fix damage in the host's mechanical limbs. Heals 1 brute and burn spread across damaged limbs. Does not consume nanites if the limbs are undamaged. 0.5 -- -- Basic Necrosis
Selective Blood Purification The nanites purge 1 toxin damage and 1u toxin reagents from the host's bloodstream, while ignoring non-toxin chemicals. The added processing power required to analyze the chemicals severely increases the nanite consumption rate. 2 -- -- Harmonic Hypoxemia, Necrosis
Bio-Reconstruction The nanites manually repair and replace organic cells, acting much faster than normal regeneration. However, this program cannot detect the difference between harmed and unharmed, causing it to consume nanites even if it has no effect. Heals 2 brute and burn damage. 5.5 -- -- Harmonic Hypoxemia, Necrosis
Neural Reimaging The nanites are able to backup and restore the host's neural connections, potentially replacing entire chunks of missing or damaged brain matter. Heals 2 brain damage and has 10% chance to heal up to lobotomy level brain traumas. 3 -- -- Harmonic Neuro-Necrosis, Brain Misfire
Defibrillation The nanites shock the host's heart when triggered, bringing them back to life if the body can sustain it. The revive has the same requirements to work as an ordinary defibrillation, except the revive will not heal toxin or suffocation damage, and will not deal any suffocation damage. This means the body must have under 180 total of all basic damage types + cellular. The ghost gets a message and 8 seconds to re-enter their body after the trigger. -- 25 12s Harmonic Shocking

Glitch Programs[править | править код]

Defective programs caused by data corruption, and not otherwise obtainable. Generally range from mildly to moderately dangerous. Can stack.

Program Effect Volume per second Trigger Cost Trigger Cooldown Required Techweb Corruptions
Glitch A heavy software corruption that causes nanites to gradually break down. 1.5 -- -- -- None
Necrosis The nanites attack internal tissues indiscriminately, causing widespread damage. 0.75 -- -- -- Glitch
Toxin Buildup The nanites cause a slow but constant toxin buildup inside the host. 0.25 -- -- -- Glitch
Hypoxemia The nanites prevent the host's blood from absorbing oxygen efficiently. 0.75 -- -- -- Glitch
Neuro-Necrosis The nanites seek and attack brain cells, causing extensive neural damage to the host. 0.75 -- -- -- Necrosis
Brain Misfire The nanites interfere with neural pathways, causing minor psychological disturbances. 0.5 -- -- -- Neuro-Necrosis
Dermalysis The nanites attack skin cells, causing irritation, rashes, and minor damage. 0.25 -- -- -- Necrosis
Nerve Decay The nanites attack the host's nerves, causing lack of coordination and short bursts of paralysis. 1 -- -- -- Necrosis

Weaponized Programs[править | править код]

Aggressive programs which use nanites as a military-grade weapon. Moderately to extremely dangerous to the host and/or their surroundings.

Program Effect Volume per second Trigger Cost Trigger Cooldown Required Techweb Corruptions
Cellular Breakdown The nanites destroy cellular structures in the host's body, causing brute damage. 1.5 -- -- Biological Necrosis
Poisoning The nanites deliver poisonous chemicals to the host's internal organs, causing toxin damage and vomiting. 1.5 -- -- Biological Toxin Buildup
Memory Leak This program invades the memory space used by other programs, causing frequent corruptions and errors. 0 -- -- Smart Toxin Buildup
Aggressive Replication Nanites will consume organic matter to improve their replication rate, damaging the host. -1 -- -- Harmonic Necrosis
Meltdown Causes an internal meltdown inside the nanites, causing internal burns inside the host as well as rapidly destroying the nanite population. Sets the nanites' safety threshold to 0 when activated. 10 -- -- Military Glitch
Chain Detonation Detonates all the nanites inside the host in a chain reaction when triggered. 0 25 10s Military Toxin Buildup
Cryogenic Treatment The nanites rapidly sink heat through the host's skin, lowering their temperature. 1 -- -- Mesh Dermalysis, Sub-Dermal Combustion
Sub-Dermal Combustion The nanites cause buildup of flammable fluids under the host's skin, then ignites them. 4 -- -- Military Dermalysis, Cryogenic Treatment
Mind Control The nanites imprint an absolute directive onto the host's brain for 60 seconds when triggered. Can be used with a Comm Remote. -- 30 180s Hazard Neuro-Necrosis, Brain Misfire

Suppression Programs[править | править код]

Programs with the goal of acting as a deterrent against the host. Generally nonlethal.

Program Effect Volume per second Trigger Cost Trigger Cooldown Required Techweb Corruptions
Electric Shock The nanites shock the host when triggered. This will still harm nanites, causing volume loss and potential program errors. -- 10 30s Mesh Toxin Buildup
Neural Shock The nanites pulse the host's nerves when triggered, inapacitating them for a short period. -- 4 30s Neural Electric Shock, Nerve Decay
Sleep Induction The nanites cause rapid (but not instant) narcolepsy when triggered. -- 15 120s Synaptic Neuro-Necrosis, Brain Misfire
Paralysis The nanites actively suppress nervous pulses, effectively paralyzing the host while active. 3 -- -- Neural Nerve Decay
Happiness Enhancer The nanites synthesize serotonin inside the host's brain, creating an artificial sense of happiness. 0.1 -- -- Neural Neuro-Necrosis
Happiness Suppressor The nanites suppress the production of serotonin inside the host's brain, creating an artificial state of depression. 0.1 -- -- Neural Neuro-Necrosis
Death Simulation The nanites induce a death-like coma into the host, able to fool most medical scans. 3.5 -- -- Harmonic Necrosis, Nerve Decay, Neuro-Necrosis
Pacification The nanites suppress the aggression center of the brain, preventing the host from causing direct harm to others. 1 -- -- Synaptic Neuro-Necrosis, Brain Misfire
Blindness The nanites suppress the host's ocular nerves, blinding them while they're active. 1.5 -- -- Synaptic Nerve Decay
Mute The nanites suppress the host's speech, making them mute while they're active. 0.75 -- -- Synaptic Neuro-Necrosis, Brain Misfire
Forced Speech The nanites force the host to say a pre-programmed sentence when triggered. -- 3 2s Synaptic Neuro-Necrosis, Brain Misfire
Skull Echo The nanites echo a synthesized message inside the host's skull. -- 1 2s Smart Neuro-Necrosis, Brain Misfire
Hallucination The nanites make the host hallucinate something when triggered. -- 4 8s Synaptic Brain Misfire

Sensor Programs[править | править код]

Programs that will self-pulse a given code when their condition is met.

Program Effect Volume per second Trigger Cost Trigger Cooldown Required Techweb Corruptions
Health Sensor The nanites receive a signal when the host is above/below a certain percentage of health, with crit being 0. 0 -- -- Biological Glitch
Critical Health Sensor The nanites receive a signal when the host first reaches critical health. 0 -- -- Biological Glitch
Death Sensor The nanites receive a signal when they detect the host is dead. 0 -- -- Biological Glitch
Nanite Volume Sensor The nanites receive a signal when the nanite supply is above/below a certain percentage, with the safety threshold being 0%. If safety threshold is higher, it will skew the percentage. For example, with threshold 50, 100 volume will count as 50 available volume, which means 10% instead of 20%, and the full 500 volume will count as 90%. 0 -- -- Basic Glitch
Damage Sensor The nanites receive a signal when a host's specific damage type is above/below a target value. 0 -- -- Biological Glitch
Voice Sensor Sends a signal when the nanites hear a determined word or sentence. 0 -- -- Smart Glitch
Species Sensor When triggered, the nanites scan the host and output a signal if the host's species matches the one set in the program's settings. The options include "Human", "Lizard", "Moth", "Ethereal", "Pod", "Fly", "Felinid", "Jelly" and "Other". Secondary toggle is either "Is" or "Is Not". -- -- -- Biological Glitch