Редактирование:
Guide to power
(раздел)
Перейти к навигации
Перейти к поиску
Внимание:
Вы не вошли в систему. Ваш IP-адрес будет общедоступен, если вы запишете какие-либо изменения. Если вы
войдёте
или
создадите учётную запись
, её имя будет использоваться вместо IP-адреса, наряду с другими преимуществами.
Анти-спам проверка.
Не
заполняйте это!
= Power Distribution = == Power Grid == To most people they're just wires that burn the shit out of you when you try to cut them without wearing insulated gloves. But really, the power grid is the electrical backbone of the station, powering everything from the emitters containing the singularity to the APC that controls the bathrooms in the locker room that you never go to. Also, it burns the shit out of you if you try to cut it without wearing insulated gloves. == SMES == [[File:SMES_Charging.gif]] A Superconducting Magnetic Energy Storage (SMES) Cell is the spess version of a giant rechargeable battery. The standard set-up for an SMES involves: 1. a wiring input from a power source, such as Solars or the Singularity Engine, or from the power grid itself, in the case of the Backups SMESs, and 2. a wiring output to the local power grid, or to a closed system like the AI or mining stations === SMES Properties === SMES have a modifiable storage capacity, dependent on the [[power cell]]s installed in the SMES upon fabrication. All SMESs present at the beginning of a typical shift have a default capacity of 3.33 MJ. {| class ="wikitable" |+ SMES Capacity vs Power Cell ! rowspan = 2|Power Cell !! colspan = 2|Capacity |- ! per cell installed !! per 5 cells installed |- ! colspan = 3|Typical |- | [[Power Cell|Standard]] || 1.33 MJ || 6.66 MJ |- | High-Capacity || 13.33 MJ || 66.66 MJ |- | Super-Capacity || 26.66 MJ || 133.33 MJ |- | Hyper-Capacity || 40.00 MJ || 200.00 MJ |+ ! colspan = 3|Atypical |- | [[Potato Cell]] || 0.40 MJ || 2 MJ |- | [[Cyborg Cell]] || TBD || TBD |- | [[Slime Core/SMES Cell]] || TBD || TBD |} SMES input (charging) and output levels can be modified using [[capacitor]]s. All SMESs present at the beginning of a typical shift have a basic capacitor with default i/o levels of 200 kW. {| class ="wikitable" |+ SMES Input/Output Levels vs Capacitor ! Capacitor !! Max Input Level !! Max Output Level |- | [[Capacitor|Basic]] || 200000 W (200 kW) || 200000 W (200 kW) |- | Advanced || 400000 W (400 kW) || 400000 W (400 kW) |- | Super || 600000 W (600 kW) || 600000 W (600 kW) |- | Quadratic || 800000 W (800 kW) || 800000 W (800 kW) |} SMESs will only output when the level of charge is above the output level specified on the SMES settings panel. == [[APC|APCs]] == [[File:APC2.gif]] APCs, or Automated Power Controllers, are found on the walls of the room they're powering or, more likely, in maintenance just outside the room. They can be used to toggle the room's equipment, lighting and environmental (a.k.a. ventilation) systems on and off.
Описание изменений:
Пожалуйста, учтите, что любой ваш вклад в проект «MassMeta» может быть отредактирован или удалён другими участниками. Если вы не хотите, чтобы кто-либо изменял ваши тексты, не помещайте их сюда.
Вы также подтверждаете, что являетесь автором вносимых дополнений, или скопировали их из источника, допускающего свободное распространение и изменение своего содержимого (см.
MassMeta:Авторские права
).
НЕ РАЗМЕЩАЙТЕ БЕЗ РАЗРЕШЕНИЯ ОХРАНЯЕМЫЕ АВТОРСКИМ ПРАВОМ МАТЕРИАЛЫ!
Отменить
Справка по редактированию
(в новом окне)
Навигация
Персональные инструменты
Вы не представились системе
Обсуждение
Вклад
Создать учётную запись
Войти
Пространства имён
Статья
Обсуждение
русский
Просмотры
Читать
Править
Править код
История
Ещё
Поиск
/tg/station 13
Главная страница
Новым игрокам
Правила
Профессии
Гайды
Предметы
Локации
Карты
Игровые режимы
Вклад
Руководство по участию в разработке билда
Маппинг
Спрайтинг
Руководство по пониманию кода
Разработка
Wiki
Свежие правки
Случайная страница
Инструменты
Ссылки сюда
Связанные правки
Служебные страницы
Сведения о странице